MATERIAL: PVC

CABLE TYPE: SINGLE CORE


N07V-K

Lighting technology cables

Flexible red copper

Certifications

Applications
Lighting technology cables

Type of electrical conductor
Flexible red copper

Main rule
CEI 20-22/2, UNEL 35752, EN 50267-2-1

Conductor
UNEL 35752

Self-extinguishing
EN 60332-1-2; IEC 60332-1-2; CEI 20-22 II

Cable marking
ELETTRO BRESCIA IEMMEQU <HAR> CEI 20-22 II

Sections
Nominal section Max wire diameter Conductor diameter Insulation thickness Average sheath thickness Average diameter ± 0,2 Copper electric resistance 20°C Indicative
weight
CU
Factor
(N x mm²) (mm) (mm) (mm) (mm) (mm) (Ω/km) (kg/km) (kg/km)
1x1,00 0,21 1,215 0,70 - 2,7 19,50 16 9,6
1x1,50 0,26 1,435 0,70 - 3,0 13,30 21 14,4
1x2,50 0,26 1,879 0,80 - 3,6 7,98 32 24
1x4,00 0,31 2,445 0,80 - 4,1 4,95 45 38,4
1x6,00 0,31 2,955 0,80 - 4,7 3,30 67 57,6
1x10,00 0,41 3,992 1,00 - 6,2 1,91 121 96
1x16,00 0,41 5,20 1,00 - 7,4 1,21 188 153,6
1x25,00 0,41 6,50 1,20 - 9,1 0,78 292 240
1x35,00 0,41 7,70 1,20 - 10,3 0,55 406 336
1x50,00 0,41 9,30 1,40 - 12,3 0,38 577 480
1x70,00 0,51 10,80 1,40 - 13,8 0,27 797 672
1x95,00 0,51 13,60 1,60 - 17,0 0,20 1050 912
1x120,00 0,51 14,80 1,60 - 18,2 0,16 1330 1150
1x150,00 0,51 17,40 1,80 - 21,2 0,12 1682 1440
 

Documents:

Certificate

 

 

MATERIAL: SILICONE

CABLE TYPE: SINGLE CORE


N2GFA (N)2GFA

Lighting technology cables

Solid tinned copper

Certifications

Applications
Lighting technology cables

Type of electrical conductor
Solid tinned copper

Main rule
VDE 0250 TEIL 502

Conductor
EN 60228; IEC 60228

Cable marking
N2GFA (N)2GFA ELETTRO BRESCIA <VDE> Reg. Nr. 7874

Sections
Nominal section Max wire diameter Conductor diameter Insulation thickness Average sheath thickness Average diameter ± 0,2 Copper electric resistance 20°C Indicative
weight
CU
Factor
(N x mm²) (mm) (mm) (mm) (mm) (mm) (Ω/km) (kg/km) (kg/km)
1x0,50 0,80 0,80 0,60 - 2,1 36,70 - 4,8
1x0,75 1,00 1,00 0,60 - 2,3 24,80 - 7,2
1x1,00 1,13 1,13 0,60 - 2,4 18,20 - 9,6
1x1,50 1,35 1,35 0,70 - 2,9 12,20 - 14,4
1x2,50 1,75 1,75 0,80 - 3,5 7,56 - 24
 

Documents:

Certificate

 

 

MATERIAL: SILICONE

CABLE TYPE: SINGLE CORE


N2GFAF (N)2GFAF

Lighting technology cables

Flexible red copper

Certifications

Applications
Lighting technology cables

Type of electrical conductor
Flexible red copper

Main rule
VDE 0250 TEIL 502

Conductor
EN 60228; IEC 60228

Cable marking
N2GFAF - (N)2GFAF ELETTRO BRESCIA <VDE> Reg. Nr. 7874

Sections
Nominal section Max wire diameter Conductor diameter Insulation thickness Average sheath thickness Average diameter ± 0,2 Copper electric resistance 20°C Indicative
weight
CU
Factor
(N x mm²) (mm) (mm) (mm) (mm) (mm) (Ω/km) (kg/km) (kg/km)
1x0,50 0,21 0,859 0,60 - 2,2 39,00 - 4,8
1x0,75 0,21 1,052 0,60 - 2,4 26,00 - 7,2
1x1,00 0,21 1,215 0,60 - 2,5 19,50 - 9,6
1x1,50 0,26 1,435 0,70 - 3,0 13,30 - 14,4
1x2,50 0,26 1,879 0,80 - 3,6 7,98 - 24
 

Documents:

Certificate

 

 

MATERIAL: SILICONE

CABLE TYPE: SINGLE CORE


N2GFA (N)2GFA

Lighting technology cables

Solid red copper

Certifications

Applications
Lighting technology cables

Type of electrical conductor
Solid red copper

Main rule
VDE 0250 TEIL 502

Conductor
EN 60228; IEC 60228

Cable marking
N2GFA (N)2GFA ELETTRO BRESCIA <VDE> Reg. Nr. 7874

Sections
Nominal section Max wire diameter Conductor diameter Insulation thickness Average sheath thickness Average diameter ± 0,2 Copper electric resistance 20°C Indicative
weight
CU
Factor
(N x mm²) (mm) (mm) (mm) (mm) (mm) (Ω/km) (kg/km) (kg/km)
1x0,50 0,80 0,80 0,60 - 2,1 36,70 - 4,8
1x0,75 1,00 1,00 0,60 - 2,3 24,80 - 7,2
1x1,00 1,13 1,13 0,60 - 2,4 18,20 - 9,6
1x1,50 1,35 1,35 0,70 - 2,9 12,20 - 14,4
1x2,50 1,75 1,75 0,80 - 3,5 7,56 - 24
 

Documents:

Certificate

 

 

MATERIAL: SILICONE

CABLE TYPE: SINGLE CORE


N2GFAF (N)2GFAF

Lighting technology cables

Flexible tinned copper

Certifications

Applications
Lighting technology cables

Type of electrical conductor
Flexible tinned copper

Main rule
VDE 0250 TEIL 502

Conductor
EN 60228; IEC 60228

Cable marking
N2GFAF - (N)2GFAF ELETTRO BRESCIA <VDE> Reg. Nr. 7874

Sections
Nominal section Max wire diameter Conductor diameter Insulation thickness Average sheath thickness Average diameter ± 0,2 Copper electric resistance 20°C Indicative
weight
CU
Factor
(N x mm²) (mm) (mm) (mm) (mm) (mm) (Ω/km) (kg/km) (kg/km)
1x0,50 0,21 0,859 0,60 - 2,2 40,10 - 4,8
1x0,75 0,21 1,052 0,60 - 2,4 26,70 - 7,2
1x1,00 0,21 1,215 0,60 - 2,5 20,00 - 9,6
1x1,50 0,26 1,485 0,70 - 3,0 13,70 - 14,4
1x2,50 0,26 1,918 0,80 - 3,6 8,21 - 24
 

Documents:

Certificate